Special Tools
EL-35616 Terminal Test Probe Kit
For equivalent regional tools, refer to Special Tools.
When the condition is not currently present, but is indicated in DTC history, the cause may be intermittent. An intermittent may also be the cause when there is a customer complaint, but the symptom cannot be duplicated: Refer to the Symptom Table of the system that is suspect of causing the condition before trying to locate an intermittent condition.
Most intermittent conditions are caused by faulty electrical connections or wiring. Inspect for the following items:
Testing for Terminal Fretting
Some intermittent conditions can be caused by wire terminal fretting corrosion. Fretting corrosion is a build-up of insulating, oxidized wear debris that can form when there is a small motion between electrical contacts. The oxidized wear debris can pile up enough at the electrical contact spots that the electrical resistance across the connection increases. Movement between the contacting surfaces as small as 10 to 100 microns can cause fretting.
To put this in perspective, a sheet of paper is about 100 microns thick, so fretting motion is small and hard to see.
Vibration and thermal expansion/contraction are the main sources that create fretting motion. Since vehicles vibrate and can experience large temperature swings, they are a good source for fretting motion. Tin, copper, nickel, and iron surfaces are all susceptible to fretting corrosion. Fretting corrosion can be difficult to see but it looks like small, dark smudges on the terminals contact surface.
To correct a fretting condition disconnect the suspect connector and add dielectric grease / lubricant (Nyogel 760G or equivalent, meeting GM specification 9986087) to both sides of the connector terminals. Then reconnect the connector and wipe away any excess lubricant. This will correct the additional terminal contact resistance due to the terminal fretting corrosion.
Testing for Proper Terminal Contact
It is important to test terminal contact at the component and any inline connectors before replacing a suspect component. Mating terminals must be inspected to ensure good terminal contact. A poor connection between the male and female terminal at a connector may be the result of contamination or deformation.
Contamination may be caused by the connector halves being improperly connected. A missing or damaged connector seal, damage to the connector itself, or exposing the terminals to moisture and dirt can also cause contamination. Contamination, usually in the underhood or underbody connectors, leads to terminal corrosion, causing an open circuit or intermittently open circuit.
Deformation is caused by probing the mating side of a connector terminal without the proper adapter. Always use the EL-35616 kit when probing connectors. Other causes of terminal deformation are improperly joining the connector halves, or repeatedly separating and joining the connector halves. Deformation, usually to the female terminal contact tang, can result in poor terminal contact causing an open or intermittently open circuit.
Testing for Proper Terminal Contact in Bussed Electrical Centers
It is very important to use the correct test adapter when testing for proper terminal contact of fuses and relays in a bussed electrical center. Use the EL-35616 kit to test for proper terminal contact. Failure to use the EL-35616 kit can result in improper diagnosis of the bussed electrical center.
Follow the procedure below in order to test terminal contact:
1. Separate the connector halves.
2. Visually inspect the connector halves for contamination. Contamination may result in a white or green buildup within the connector body or between terminals. This causes high terminal resistance, intermittent contact, or an open circuit. An underhood or underbody connector that shows signs of contamination should be replaced in its entirety: terminals, seals, and connector body.
3. Using an equivalent male terminal/terminated lead, verify that the retention force is significantly different between a known good terminal and the suspect terminal. Replace the female terminal in question.
Flat Wire Connectors
There are no serviceable parts for flat wire connectors on the harness side or the component side.
Follow the procedure below in order to test terminal contact:
1. Remove the component in question.
2. Visually inspect each side of the connector for signs of contamination. Avoid touching either side of the connector as oil from your skin may be a source of contamination as well.
3. Visually inspect the terminal bearing surfaces of the flat wire circuits for splits, cracks, or other imperfections that could cause poor terminal contact. Visually inspect the component side connector to ensure that all of the terminals are uniform and free of damage or deformation.
4. Insert the appropriate adapter into the flat wire harness connector in order to test the circuit in question.
Control Module/Component Voltage and Grounds
Poor voltage or ground connections can cause widely varying symptoms.
Temperature Sensitivity
The condition may occur only when the component/connection is cold, or only when the component/connection is hot.
Electromagnetic Interference and Electrical Noise
Some electrical components/circuits are sensitive to electromagnetic interference or other types of electrical noise.
Inspect for the following conditions:
Incorrect Control Module
NOTE: DO NOT re-program the control module with the SAME software/calibration files that are already present in the control module. This is not an effective repair for any type of concern.